Exabyte MAGNUM 1X7 LTO AUTOLOADER Instrukcje Operacyjne Strona 168

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 242
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 167
18-2
SCSI REFERENCE 1012975
CHAPTER 18—REQUEST SENSE (03h)
The REQUEST SENSE command was issued to an unsupported LUN. In this
case, the autoloader does not return Check Condition status and returns the
following sense data:
If no sense data is available for the specified I_T_L nexus, the autoloader
returns the following sense data:
18.2 WHAT YOU SEND TO THE AUTOLOADER
Allocation Length – Byte 04
This field indicates the number of bytes that the initiator has allocated for
returned sense data. The autoloader provides a total of 14h (20) bytes of sense
data.
Sense key Illegal Request (5h)
ASC Logical unit not supported (25h)
ASCQ 00h
Sense key No Sense (0h)
ASC No additional sense information (00h)
ASCQ 00h