Exabyte EXB-8205 Instrukcje Operacyjne Strona 235

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 446
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 234
PEOT or PEOP Encountered
During a read operation, if the CTS encounters the physical end of
tape (PEOT) or the physical end of partition (PEOP) for 8500c format
only, it returns Check Condition status. The REQUEST SENSE data is
set as follows:
Valid 0 or 1
EOM 1
Sense Key Volume Overflow (Dh)
Information
bytes
If Valid=1, depend on the setting of the Fixed bit, as follows:
If the Fixed bit is 0, equal the requested transfer length
If the Fixed bit is 1, equal the difference between the
requested transfer length and the actual number of
logical blocks read.
ASC 00h
ASCQ 02h
PEOT 1
FSC 14h
When the READ command terminates, the logical position is
undefined.
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
12-7
12 READ (08h)
Przeglądanie stron 234