Exabyte EXB-8205 Instrukcje Operacyjne Strona 239

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 446
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 238
Compression Errors
The CTS can report two types of compression errors during a read
operation:
If the compression circuit is unable to decompress previously
compressed data during a read operation, the CTS returns Check
Condition status. The REQUEST SENSE data is set as follows:
Sense Key Hardware Error (4h)
ASC 11h
ASCQ 00h
FSC 18h
If the read decompression CRC fails during a read operation, the
CTS returns Check Condition status. The REQUEST SENSE data
is set as follows:
Sense Key Hardware Error (4h)
ASC 11h
ASCQ 02h
FSC 19h
To recover from either of these errors, follow these steps:
1. Reissue the failed command or command sequence.
2. Power the CTS off and back on again.
or
Send a SCSI bus reset (“hard” reset).
If the error persists, the CTS requires service.
May 1994 EXB-8205 and EXB-8505
(Standard and XL)
12-11
12 READ (08h)
Przeglądanie stron 238
1 2 ... 234 235 236 237 238 239 240 241 242 243 244 ... 445 446

Komentarze do niniejszej Instrukcji

Brak uwag